温控箱,容量:335升Weiss
WT3-340/40 -42°C bis +180°C
温控箱,容量:335升
Weiss
WT3-340/40 -42°C bis +180°C
状况
二手
位置
Borken 

机器数据
价格和位置
- 位置:
- Einsteinstraße 8a, 46325 Borken, Deutschland

拨打
优惠详情
- 广告编号:
- A22185222
- 参考编号:
- 23961
- 更新:
- 最近更新时间为 23.06.2026
描述
Here, we offer a Weiss temperature chamber.
Weiss temperature test chamber with S!MCON / 32 control, water-cooled.
(Refrigerant converted to R-452A)
Control panel: "Touchpanel"
On the "Touchpanel" control panel, all control and operating commands can be initiated by simply touching the function symbols.
Adjustable feet
To compensate for unevenness in the floor and to ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be placed in the test chamber.
Feedthrough installed as standard:
R1: 125 mm
L1: 50 mm
Test chamber volume: approx. 335 liters
Test chamber dimensions: height 750 mm, width 580 mm, depth 765 mm
External dimensions: height 1775 mm, width 870 mm, depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 3.2 K/min
Cooling: 4.0 K/min
Maximum heat compensation: 2300 W
Data for operation:
Test chamber lighting: 2 x 24V, 50W halogen lamps
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 14 A, rated power 4.1 kW
Kodpozgbkhefx Al Rjnb
Fuse: 16 A slow-blow (provided on-site)
Sound pressure level: approx.
measured at a distance of 1m from the front, 1m height: 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
Type: WT3-340/40
For your safety as a buyer, here is the following information:
The following steps are performed on our offered chambers in advance:
1. Function check and replacement of any necessary components.
2. If necessary, refilling with legally compliant refrigerant.
3. Leak test with certificate.
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
该广告为自动翻译,可能存在翻译错误。
Weiss temperature test chamber with S!MCON / 32 control, water-cooled.
(Refrigerant converted to R-452A)
Control panel: "Touchpanel"
On the "Touchpanel" control panel, all control and operating commands can be initiated by simply touching the function symbols.
Adjustable feet
To compensate for unevenness in the floor and to ensure adequate ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be placed in the test chamber.
Feedthrough installed as standard:
R1: 125 mm
L1: 50 mm
Test chamber volume: approx. 335 liters
Test chamber dimensions: height 750 mm, width 580 mm, depth 765 mm
External dimensions: height 1775 mm, width 870 mm, depth 1600 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 3.2 K/min
Cooling: 4.0 K/min
Maximum heat compensation: 2300 W
Data for operation:
Test chamber lighting: 2 x 24V, 50W halogen lamps
Rated voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 14 A, rated power 4.1 kW
Kodpozgbkhefx Al Rjnb
Fuse: 16 A slow-blow (provided on-site)
Sound pressure level: approx.
measured at a distance of 1m from the front, 1m height: 56 dB(A)
Refrigerant: R-452A
Weight: 515 kg
Type: WT3-340/40
For your safety as a buyer, here is the following information:
The following steps are performed on our offered chambers in advance:
1. Function check and replacement of any necessary components.
2. If necessary, refilling with legally compliant refrigerant.
3. Leak test with certificate.
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
该广告为自动翻译,可能存在翻译错误。
发送询价
电话 & 传真
+49 2861 ... 广告
这些广告您可能也感兴趣。
成功
您的消息已发送。
小广告
Moers
7,451 km
保温容器 780升冷藏单元
TKTC-780
TKTC-780
成功
您的消息已发送。
小广告
Aichach
7,327 km
卷臂钩自卸卡车
MERCEDES-BENZ4144 Actros MP2 Abrollkipper 8x8 Singlebereifung
MERCEDES-BENZ4144 Actros MP2 Abrollkipper 8x8 Singlebereifung
成功
您的消息已发送。
小广告
Iserlohn
7,397 km
通用试验机 Zwick 200千牛
ZwickRoell1488
ZwickRoell1488
成功
您的消息已发送。
小广告
Terrassa
8,336 km
真空泵
Marpa Vacuum compatible con BeckerMVS-V025 compatible con VT 4.25/ VX4.25/
Marpa Vacuum compatible con BeckerMVS-V025 compatible con VT 4.25/ VX4.25/
成功
您的消息已发送。
小广告
德国
7,100 km
磨杯机
LapidelloVAM300
LapidelloVAM300
成功
您的消息已发送。
小广告
Ybbs an der Donau
7,077 km
傅立叶变换红外光谱仪 - NICOLET IS20
ThermoFisher ScientificNICOLET IS20
ThermoFisher ScientificNICOLET IS20
成功
您的消息已发送。
小广告
Borken
7,417 km
真空泵 16 m/h 2 阶段
LeyboldTrivac D 16 B
LeyboldTrivac D 16 B
成功
您的消息已发送。
小广告
Babberich
7,456 km
160吨液压机
WMW ZeulenrodaPYE 160 SS
WMW ZeulenrodaPYE 160 SS
成功
您的消息已发送。
小广告
Meiningen
7,262 km
烤漆干燥机 DIN 1539 300°C
VötschVTL 100/150 nach DIN 1539
VötschVTL 100/150 nach DIN 1539
成功
您的消息已发送。
小广告
Schwäbisch Gmünd
7,398 km
线切割机床
SodickAQ537L, AQ 327L und AG 60L
SodickAQ537L, AQ 327L und AG 60L
您的广告已成功删除
发生错误