KEYENCE IM-7030TKEYENCE
IM-7030T
KEYENCE IM-7030T
KEYENCE
IM-7030T
出厂年份
2018
状况
二手
位置
拉脱维亚 

基本数据
价格和位置
- 位置:
- , 拉脱维亚

拨打
优惠详情
- 广告编号:
- A20702060
- 参考编号:
- LV-MEA-KEY-2018-00001
- 更新:
- 最近更新时间为 22.10.2026
描述
This KEYENCE IM-7030T optical measurement machine was manufactured in 2018. It features a 10.4" LCD monitor, a double telecentric lens, and motorized XY and Z stages with a movement range of 200 × 100 mm and 75 mm respectively. It supports both wide-field and high-precision measurement modes, ensuring detailed and accurate measurements. Consider the opportunity to buy this KEYENCE IM-7030T optical measurement machine. Contact us for more information about this machine.
• Controller: IM-7000
• Image pickup device: 1" 6.6 megapixel monochrome CMOS
• Display: 10.4" LCD monitor (XGA 1024×768)
• Light receiving lens: Double telecentric lens
• Illumination system: Telecentric transmissive, top light, four-division multi-angle illumination (motorized), slit ring illumination (motorized)
• Measurement modes: Wide-field, High-precision
• Wide-field measurement area: 300 × 200 mm (quadangle R50)
• High-precision measurement area: 225 × 125 mm
• Minimum display unit: 0.1 µm
• Measurement accuracy (wide-field, without stage move): ±1 µm
• Measurement accuracy (high-precision, without stage move): ±0.5 µm
• Measurement accuracy (wide-field, with stage move): ±2 µm
• Measurement accuracy (high-precision, with stage move): ±1.5 µm
• Linked measurement accuracy: ±(7 + 0.02L) µm (wide-field), ±(4 + 0.02L) µm (high-precision)
• Measurable area (XY, stage): 90 × 90 mm
• Maximum measurement depth: 30 mm
• Light probe diameter: 3 mm
• Measuring force: 0.015 N (light probe), 0.3 N (height measurement)
• Repetition accuracy: ±2 µm
• Measurement range (Z): 0–75 mm
• Measuring position accuracy (XY): ±0.2 mm
• Minimum display unit (height): 1 µm
• Measurable area (XY) wide-field mode: 145 × 95 mm
• Measurable area (XY) high-precision mode: 107.5 × 95 mm
• XY stage: Motorized, movement range 200 × 100 mm, max load 5 kg
• Z stage: Motorized, movement range 75 mm
• External remote input: Non-voltage input (contact/solid-state)
• External output: PhotoMOS, OK/NG/FAIL/MEAS, rated load 24 VDC, 0.5 A
• Interface: LAN RJ-45 (10/100/1000BASE-T), USB 2.0 Series A (6 ports)
• Record storage: HDD 500 GB
• Ambient temperature: +10 to +35°C
• Relative humidity: 20–80% RH (no condensation)
Bedpfx Aox D E Npjlrelp
• Pollution degree: 2
• Over-voltage category: II
• Power supply voltage: 100–240 V, 50/60 Hz
• Weight head: 31 kg
• Controller weight: ~8 kg
• Controller: IM-7000
• Image pickup device: 1" 6.6 megapixel monochrome CMOS
• Display: 10.4" LCD monitor (XGA 1024×768)
• Light receiving lens: Double telecentric lens
• Illumination system: Telecentric transmissive, top light, four-division multi-angle illumination (motorized), slit ring illumination (motorized)
• Measurement modes: Wide-field, High-precision
• Wide-field measurement area: 300 × 200 mm (quadangle R50)
• High-precision measurement area: 225 × 125 mm
• Minimum display unit: 0.1 µm
• Measurement accuracy (wide-field, without stage move): ±1 µm
• Measurement accuracy (high-precision, without stage move): ±0.5 µm
• Measurement accuracy (wide-field, with stage move): ±2 µm
• Measurement accuracy (high-precision, with stage move): ±1.5 µm
• Linked measurement accuracy: ±(7 + 0.02L) µm (wide-field), ±(4 + 0.02L) µm (high-precision)
• Measurable area (XY, stage): 90 × 90 mm
• Maximum measurement depth: 30 mm
• Light probe diameter: 3 mm
• Measuring force: 0.015 N (light probe), 0.3 N (height measurement)
• Repetition accuracy: ±2 µm
• Measurement range (Z): 0–75 mm
• Measuring position accuracy (XY): ±0.2 mm
• Minimum display unit (height): 1 µm
• Measurable area (XY) wide-field mode: 145 × 95 mm
• Measurable area (XY) high-precision mode: 107.5 × 95 mm
• XY stage: Motorized, movement range 200 × 100 mm, max load 5 kg
• Z stage: Motorized, movement range 75 mm
• External remote input: Non-voltage input (contact/solid-state)
• External output: PhotoMOS, OK/NG/FAIL/MEAS, rated load 24 VDC, 0.5 A
• Interface: LAN RJ-45 (10/100/1000BASE-T), USB 2.0 Series A (6 ports)
• Record storage: HDD 500 GB
• Ambient temperature: +10 to +35°C
• Relative humidity: 20–80% RH (no condensation)
Bedpfx Aox D E Npjlrelp
• Pollution degree: 2
• Over-voltage category: II
• Power supply voltage: 100–240 V, 50/60 Hz
• Weight head: 31 kg
• Controller weight: ~8 kg
这些广告您可能也感兴趣。
成功
您的消息已发送。
小广告
奥地利
7,492 km
KEYENCE IM-7030T
KEYENCEIM-7030T
KEYENCEIM-7030T
成功
您的消息已发送。
小广告
Bienne
7,647 km
立式加工中心
WilleminW-508 MT
WilleminW-508 MT
成功
您的消息已发送。
小广告
Sremska Mitrovica
6,911 km
只有隔音舱
for BRUDERER pressesSound insulating cabin
for BRUDERER pressesSound insulating cabin
成功
您的消息已发送。
小广告
Saarbrücken
7,557 km
测量显微镜/多传感器测量机
MahrMS 222 Komplettpaket mit Lieferung*
MahrMS 222 Komplettpaket mit Lieferung*
成功
您的消息已发送。
小广告
Root
7,578 km
CNC 车铣加工中心
DOOSANPUMA MX 2600 ST
DOOSANPUMA MX 2600 ST
成功
您的消息已发送。
小广告
Wetzlar
7,381 km
铣床
CONTURMHA-5
CONTURMHA-5
成功
您的消息已发送。
小广告
Wilfersdorf
7,088 km
生产压力机 Stenhof
STENHOJLPSP 100T
STENHOJLPSP 100T
成功
您的消息已发送。
小广告
Denzlingen
7,558 km
数控车床
MAZAKQuick Turn Nexus 100-II
MAZAKQuick Turn Nexus 100-II
成功
您的消息已发送。
小广告
Hilzingen
7,516 km
Bruderer BSTA 110
BRUDERERBSTA 110
BRUDERERBSTA 110
成功
您的消息已发送。
小广告
瑞士
7,492 km
NAKAMURA NTJ100
Nakamura-TomeNTJ100
Nakamura-TomeNTJ100
您的广告已成功删除
发生错误