柴油发电机 2000千伏安Hitec
2000 kVA Diesel Generator
柴油发电机 2000千伏安
Hitec
2000 kVA Diesel Generator
製造年份
2011
狀況
二手
位置
Kaunas 

顯示圖片
显示地图
机器数据
价格和位置
- 位置:
- Pramones 23, 51287 Kaunas, Lithuania

撥打
优惠详情
- 產品ID:
- A21115332
- 最後更新:
- 於 29.01.2026
描述
2000 kVA high voltage diesel uninterruptible power supply (UPS) system with two output buses for sale
Technical data: 2000 kVA, 10 kV, 50 Hz, power factor 0.8, 1500 rpm
The system consists of:
• Power generation module (PGM) - diesel engine with optimized emissions, induction coil, synchronous generator;
• Starter;
• Battery (Pb);
• Redundant start panel RSP;
Hjdeyfprfjpfx Agmoh
• Diesel generator automatic oil lubrication equipment;
• Unit control panel UCP with touch screen and diesel reduction start
module;
• Auxiliary control panel ACP for radiator and fuel tank control;
• High voltage unit reactor panel URP, 10 kV;
• Generator transformer panel GTP 660V /400V;
• Block transformer panel UTP 10 kV/660V;
• Bypass control panel BCP and auxiliary panels DCP and ADC, BCP capable of controlling six (6) parallel operating systems with programmable logic controller PLC. DCP for powering auxiliary medium voltage DC circuits, ADC for alternating current supply to UPS control panels 400V, 320A block. Interfaces of high voltage switchgear with diesel UPS control panel via Modbus and I/0 modules.
• Monitoring - standard monitoring system for graphical and digital display of current and stored data, alarms;
• Main input power cabinet (MPB), which consists of an input input main cabinet and an output main cabinet:
• Input main power cabinet (IMPB) - metal enclosure. for medium voltage distribution, 10 kV, 16 kA - 1 sec., 50 Hz. The circuit breakers are fixed. Must be able to connect six systems operating in parallel: 2 x input circuit breakers Q7A and Q7B, l x UPS system circuit breaker 1Ql, 1 x bypass disconnection panel Q3A and a measurement panel. Must be able to transmit data to the UPS system via Modbus interface; • Output main power cabinet (OMPB) - metal closed, for medium voltage distribution, 10 kV, 16 kA - 1 sec. 50 Hz. The circuit breakers are fixed. Must be able to connect six systems operating in parallel: lx bypass circuit breaker panel 1Q3A. 1xUPS output circuit breaker 1Q2A, 1 x UPS output circuit breaker Q4A, l x UPS output disconnection Q4Ad. 2 measuring panels, 1 x output switch Q80A. Modbus interface with UPS system control panel;
• Exhaust system with muffler, exhaust manifold, two flexible connections for diesel exhaust outlets;
• Cooler with horizontal radiator cooler (directional blade fan) for diesel cooling with six flexible bellows for connecting drying pipes.
Technical data: 2000 kVA, 10 kV, 50 Hz, power factor 0.8, 1500 rpm
The system consists of:
• Power generation module (PGM) - diesel engine with optimized emissions, induction coil, synchronous generator;
• Starter;
• Battery (Pb);
• Redundant start panel RSP;
Hjdeyfprfjpfx Agmoh
• Diesel generator automatic oil lubrication equipment;
• Unit control panel UCP with touch screen and diesel reduction start
module;
• Auxiliary control panel ACP for radiator and fuel tank control;
• High voltage unit reactor panel URP, 10 kV;
• Generator transformer panel GTP 660V /400V;
• Block transformer panel UTP 10 kV/660V;
• Bypass control panel BCP and auxiliary panels DCP and ADC, BCP capable of controlling six (6) parallel operating systems with programmable logic controller PLC. DCP for powering auxiliary medium voltage DC circuits, ADC for alternating current supply to UPS control panels 400V, 320A block. Interfaces of high voltage switchgear with diesel UPS control panel via Modbus and I/0 modules.
• Monitoring - standard monitoring system for graphical and digital display of current and stored data, alarms;
• Main input power cabinet (MPB), which consists of an input input main cabinet and an output main cabinet:
• Input main power cabinet (IMPB) - metal enclosure. for medium voltage distribution, 10 kV, 16 kA - 1 sec., 50 Hz. The circuit breakers are fixed. Must be able to connect six systems operating in parallel: 2 x input circuit breakers Q7A and Q7B, l x UPS system circuit breaker 1Ql, 1 x bypass disconnection panel Q3A and a measurement panel. Must be able to transmit data to the UPS system via Modbus interface; • Output main power cabinet (OMPB) - metal closed, for medium voltage distribution, 10 kV, 16 kA - 1 sec. 50 Hz. The circuit breakers are fixed. Must be able to connect six systems operating in parallel: lx bypass circuit breaker panel 1Q3A. 1xUPS output circuit breaker 1Q2A, 1 x UPS output circuit breaker Q4A, l x UPS output disconnection Q4Ad. 2 measuring panels, 1 x output switch Q80A. Modbus interface with UPS system control panel;
• Exhaust system with muffler, exhaust manifold, two flexible connections for diesel exhaust outlets;
• Cooler with horizontal radiator cooler (directional blade fan) for diesel cooling with six flexible bellows for connecting drying pipes.
这些广告您可能也感兴趣。
小广告
Sheffield
7,807 km
立式数控车床
HankookVTB125E
HankookVTB125E
小广告
Cuggiono
7,638 km
加工中心
OkumaMILLAC 852V
OkumaMILLAC 852V
小广告
瑞士
7,605 km
龙门铣床
KOLBCUBIMAT VD
KOLBCUBIMAT VD
小广告
Zuchwil
7,627 km
外圆磨床
StuderS30-12
StuderS30-12
小广告
Groenlo
7,421 km
总计
PramacGPW60I/FS5 Valid inspection, *Guarantee! Diesel, 6
PramacGPW60I/FS5 Valid inspection, *Guarantee! Diesel, 6
小广告
Düsseldorf
7,451 km
加工中心
MORI SEIKINH 5000 DCG 40
MORI SEIKINH 5000 DCG 40
小广告
Tata
6,884 km
冷水机组 Trane RTUB224 800kW
Trane RTUB 224800kw
Trane RTUB 224800kw
小广告
芬兰
5,879 km
工业柴油发动机
Cummins
Cummins
小广告
Root
7,578 km
CNC立铣中心
IBARMIAZV 25/D600
IBARMIAZV 25/D600
小广告
Hoorn
7,476 km
混凝土泵
SchwingSP 1800 D4 125 KW
SchwingSP 1800 D4 125 KW
您的广告已成功删除
发生错误



















































































































