Weiss气候试验箱WK1-1000/70,温度范围-70°C至180°C,带湿度控制,容积990升Weiss
Klimaprüfschrank WK1-1000/70
Weiss气候试验箱WK1-1000/70,温度范围-70°C至180°C,带湿度控制,容积990升
Weiss
Klimaprüfschrank WK1-1000/70
状况
二手
位置
Borken 

基本数据
- 制造商:
- Weiss
- 状况:
- 二手
价格和位置
- 位置:
- Einsteinstraße 8a, 46325 Borken, Deutschland

拨打
优惠详情
- 广告编号:
- A22185452
- 参考编号:
- 24046
- 更新:
- 最近更新时间为 15.10.2026
描述
Weiss
Type: WK1-1000/70
Weiss Climate Test Chamber, Water-Cooled
(Refrigerant converted to R-452A)
Control Panel “Touch Panel”
All control and operating commands can be initiated on the “Touch Panel” control panel by simply touching the function symbols.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measurement cables and testing equipment to be placed in the test chamber.
Feedthroughs:
1 feedthrough, ∅ 125 mm, installed on the right
1 feedthrough, ∅ 50 mm, installed on the left
Volume: 990 liters
Test chamber dimensions:
Test chamber: Width 1100 mm, Depth 950 mm, Height 950 mm
Housing: Width 1385 mm, Depth 1850 mm, Height 1980 mm
Data for temperature tests:
Minimum temperature: -70 °C
Maximum temperature: +180 °C
Temperature deviation, temporal: ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial: ± 0.5 to ± 2 K
Temperature change rate, heating: 4 K/min
Temperature change rate, cooling: 2.5 K/min
Max. heat compensation: 2750 W
Data for climate tests:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temperature deviation, temporal: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, temporal: ± 1 to ± 3% RH
Data for operation:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 29A, Nominal power: 19.8 kW
Refrigerant: R-452A / R23
Weight: approx. 910 kg
For your safety as a buyer, here is the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Knedpfxezgbtpe Aarsc
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We would be happy to answer any further questions you may have by phone.
该广告为自动翻译,可能存在翻译错误。
Type: WK1-1000/70
Weiss Climate Test Chamber, Water-Cooled
(Refrigerant converted to R-452A)
Control Panel “Touch Panel”
All control and operating commands can be initiated on the “Touch Panel” control panel by simply touching the function symbols.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measurement cables and testing equipment to be placed in the test chamber.
Feedthroughs:
1 feedthrough, ∅ 125 mm, installed on the right
1 feedthrough, ∅ 50 mm, installed on the left
Volume: 990 liters
Test chamber dimensions:
Test chamber: Width 1100 mm, Depth 950 mm, Height 950 mm
Housing: Width 1385 mm, Depth 1850 mm, Height 1980 mm
Data for temperature tests:
Minimum temperature: -70 °C
Maximum temperature: +180 °C
Temperature deviation, temporal: ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial: ± 0.5 to ± 2 K
Temperature change rate, heating: 4 K/min
Temperature change rate, cooling: 2.5 K/min
Max. heat compensation: 2750 W
Data for climate tests:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temperature deviation, temporal: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, temporal: ± 1 to ± 3% RH
Data for operation:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 29A, Nominal power: 19.8 kW
Refrigerant: R-452A / R23
Weight: approx. 910 kg
For your safety as a buyer, here is the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Knedpfxezgbtpe Aarsc
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We would be happy to answer any further questions you may have by phone.
该广告为自动翻译,可能存在翻译错误。
发送询价
电话 & 传真
+49 2861 ... 广告
您的广告已成功删除
发生错误