质谱仪Waters
nanoACQUITY UPLCTM G2-S Q-TOF
质谱仪
Waters
nanoACQUITY UPLCTM G2-S Q-TOF
固定价格 不含增值税
€28,000
状况
二手
位置
Borken 

基本数据
价格和位置
固定价格 不含增值税
€28,000
- 位置:
- Einsteinstraße 8a, 46325 Borken, Deutschland

拨打
优惠详情
- 广告编号:
- A22215347
- 参考编号:
- 24455
- 更新:
- 最近更新时间为 26.06.2026
描述
HPLC Waters
The system consists of the following modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow Control Modules
Flow rate of 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Flow rates of 0.10 to 5.00 µl/min.
Flow control module
Flow rate of 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples, which it draws from microtiter plates or vials, into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard wash, or it can do so in less than 60 seconds,
including a double standard wash.
The sample manager accepts plates with standard footprint, 5.03” x 3.365”,
Tjdpfxezg Tzxe Abwoc
which correspond to SBS/ANSI-compliant plates (maximum height of 2.2 inches, including covers).
The sample manager can store samples at any temperature between 4 and 40 °C (39 and 104 °F)
under ambient conditions of 25 °C (77 °F) or less.
Heating and capture module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient temperature to 65 °C (149 °F).
The column base can be pivoted outwards into any position between 0° and 180°.
In the 0° “home” position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° “away” position, the analytical column can be connected to a mass spectrometer
(on the right side of the system).
The Synapt G2 is a Q-TOF-based mass spectrometer with an additional ion mobility cell,
which enables orthogonal separation of the ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used not only for peptide identification
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Operating manual
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data, information are subject to change!)
We would be happy to answer any further questions you may have by telephone.
该广告为自动翻译,可能存在翻译错误。
The system consists of the following modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow Control Modules
Flow rate of 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Flow rates of 0.10 to 5.00 µl/min.
Flow control module
Flow rate of 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples, which it draws from microtiter plates or vials, into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard wash, or it can do so in less than 60 seconds,
including a double standard wash.
The sample manager accepts plates with standard footprint, 5.03” x 3.365”,
Tjdpfxezg Tzxe Abwoc
which correspond to SBS/ANSI-compliant plates (maximum height of 2.2 inches, including covers).
The sample manager can store samples at any temperature between 4 and 40 °C (39 and 104 °F)
under ambient conditions of 25 °C (77 °F) or less.
Heating and capture module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient temperature to 65 °C (149 °F).
The column base can be pivoted outwards into any position between 0° and 180°.
In the 0° “home” position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° “away” position, the analytical column can be connected to a mass spectrometer
(on the right side of the system).
The Synapt G2 is a Q-TOF-based mass spectrometer with an additional ion mobility cell,
which enables orthogonal separation of the ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used not only for peptide identification
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Operating manual
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data, information are subject to change!)
We would be happy to answer any further questions you may have by telephone.
该广告为自动翻译,可能存在翻译错误。
发送询价
电话 & 传真
+49 2861 ... 广告
这些广告您可能也感兴趣。
成功
您的消息已发送。
小广告
Hessisch Lichtenau
7,276 km
单立柱液压机,校直机,液压冲孔框架;带液压缸的C型机架-
ECKOLDRSD 1500 - 125
ECKOLDRSD 1500 - 125
成功
您的消息已发送。
小广告
Dreieich
7,400 km
加工中心 - 立式
PINNACLELV 117 / TNC 640
PINNACLELV 117 / TNC 640
成功
您的消息已发送。
小广告
Zielona Góra
6,872 km
用于预制的工作台 - BOOSTON
BOOSTONER-00/600
BOOSTONER-00/600
成功
您的消息已发送。
小广告
Brandbu
6,798 km
用于墙体建造的工作台
RandekBS05 og BS10U
RandekBS05 og BS10U
成功
您的消息已发送。
小广告
Malax
6,159 km
RANDEK SP700横切锯
成功
您的消息已发送。
小广告
Falkenberg
6,843 km
墙线
Randek ABWall Line
Randek ABWall Line
成功
您的消息已发送。
小广告
Emmelshausen
7,465 km
铣床
HURCOVM 10 UHSi
HURCOVM 10 UHSi
成功
您的消息已发送。
小广告
Bad Sooden-Allendorf
7,256 km
开槽机
MafellSG 500 + LS 102
MafellSG 500 + LS 102
成功
您的消息已发送。
小广告
Gerolzhofen
7,302 km
Mafell 机械设备
MAFELLMKS 165 E
MAFELLMKS 165 E
成功
您的消息已发送。
小广告
Falkenberg
6,843 km
木工机械
Randek ABBS10U 80°
Randek ABBS10U 80°
您的广告已成功删除
发生错误





















































































































