质谱仪Waters
nanoACQUITY UPLCTM G2-S Q-TOF
质谱仪
Waters
nanoACQUITY UPLCTM G2-S Q-TOF
固定价格 不含增值税
€28,000
状况
二手
位置
Borken 

机器数据
价格和位置
固定价格 不含增值税
€28,000
- 位置:
- Einsteinstraße 8a, 46325 Borken, Deutschland

拨打
优惠详情
- 广告编号:
- A17902976
- 参考编号:
- 24455
- 更新:
- 最近更新时间为 04.12.2024
描述
HPLC Waters
The system consists of these modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow control modules
Flow rate from 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Laedpfx Asvcnpaeqtjc
Flow rates from 0.10 to 5.00 µl/min.
Flow control module
Flow rate from 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples it takes from microplates or vials into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard rinse, or it can do so in less than 60 seconds,
including a double standard flush.
The sample manager accepts standard impression plates, 5.03 $0.02 in. x 3.365 $0.02 in,
SBS/ANSI compliant plates (maximum height of 2.2 inches, including covers).
The sample manager can test samples at any temperature between 4 and 40 °C (39 and 104 °F)
at ambient conditions of 25 °C (77 °F) or less.
Heating and trapping module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient to 65 °C (149 °F).
The column base can be swiveled outwards to any position between 0° and 180°.
In the 0° "Home" position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° "away" position, the analytical column can be connected to a mass spectrometer
(on the right-hand side of the system).
The Synapt G2 is a Q-TOF based mass spectrometer with an additional ion mobility cell,
which enables orthogonal separation of ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used as a peptide identification only
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Instruction manual
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
该广告为自动翻译,可能存在翻译错误。
The system consists of these modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters Pal System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Flow control modules
Flow rate from 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary solvent manager
Laedpfx Asvcnpaeqtjc
Flow rates from 0.10 to 5.00 µl/min.
Flow control module
Flow rate from 0.20 to 5.00 µl/min
Sample manager
The sample manager injects the samples it takes from microplates or vials into the chromatographic flow stream.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds,
including a single standard rinse, or it can do so in less than 60 seconds,
including a double standard flush.
The sample manager accepts standard impression plates, 5.03 $0.02 in. x 3.365 $0.02 in,
SBS/ANSI compliant plates (maximum height of 2.2 inches, including covers).
The sample manager can test samples at any temperature between 4 and 40 °C (39 and 104 °F)
at ambient conditions of 25 °C (77 °F) or less.
Heating and trapping module
Inner diameter of up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient to 65 °C (149 °F).
The column base can be swiveled outwards to any position between 0° and 180°.
In the 0° "Home" position, the column base is located directly above the sample manager
and can be connected to an optional optical detector.
In the 180° "away" position, the analytical column can be connected to a mass spectrometer
(on the right-hand side of the system).
The Synapt G2 is a Q-TOF based mass spectrometer with an additional ion mobility cell,
which enables orthogonal separation of ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used as a peptide identification only
(LC-MSE data-independent acquisition), but also for denaturation and native MS analysis.
Documents & Downloads
Data sheet: Instruction manual
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
该广告为自动翻译,可能存在翻译错误。
发送询价
电话 & 传真
+49 2861 ... 广告
这些广告您可能也感兴趣。
小广告
Wald
7,481 km
光谱仪
Varian640-IR FT-IR
Varian640-IR FT-IR
小广告
Krotoszyn
6,766 km
工业蒸汽锅炉
Loos Bosch GroupU-ND 800
Loos Bosch GroupU-ND 800
小广告
Ybbs an der Donau
7,077 km
傅立叶变换红外光谱仪 - NICOLET IS20
ThermoFisher ScientificNICOLET IS20
ThermoFisher ScientificNICOLET IS20
小广告
Hadımköy
6,363 km
旋转隧道式洗衣机
INTERSONIKRT-540
INTERSONIKRT-540
小广告
Erlangen
7,279 km
7.5千瓦的螺杆压缩机,带烘干机
KaeserSM 13 T
KaeserSM 13 T
小广告
Dn10 4Es
7,771 km
单发存款人
AFTmini depositor
AFTmini depositor
小广告
Łabuńki Pierwsze
6,420 km
螺杆式压缩机
Atlas CopcoG11FF
Atlas CopcoG11FF
小广告
Velen
7,410 km
等离子切割机
HBMCUT 60
HBMCUT 60
小广告
Malawa
6,527 km
烘焙炉+装载系统
MiweTHERMO EXPRESS + ATHLET
MiweTHERMO EXPRESS + ATHLET
小广告
Bitburg
7,540 km
带冷冻干燥机的螺杆压缩机
Aircraft / FiniA-K-Max 7,5-10-270 K (IE3)
Aircraft / FiniA-K-Max 7,5-10-270 K (IE3)
您的广告已成功删除
发生错误