气候室 -75°C / +180°C (带湿度)TIRA
TCC 7120
气候室 -75°C / +180°C (带湿度)
TIRA
TCC 7120
狀況
二手
位置
Borken 

顯示圖片
显示地图
机器数据
价格和位置
- 位置:
- Einsteinstraße 8a, 46325 Borken, DE
撥打
优惠详情
- 產品ID:
- A19008626
- 參考編號:
- 24604
- 最後更新:
- 於 24.04.2025
描述
TIRA
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the usable space) ±0.1°C ... ±0.3 °C
Maximum temperature change rate
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% ÷ ±3%
Dew point range for long-term tests +2 / +94 °C
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x D x H) 1320 x 2235 x 2137 mm
Test space dimensions (L x D x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per grid: 50 kg
Maximum floor load of the test chamber: 100 kg
Refrigerants: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
Hodpfx Aewfddwedrjnu
3. Leakage test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
Type: TCC 7120
Temperature range: -75°C / +180°C
Air-cooled condenser
Temperature stability (over time and in the center of the usable space) ±0.1°C ... ±0.3 °C
Maximum temperature change rate
Heating: 4°C/min
Cooling: 3°C/min
Humidity range: 10% to 98% relative humidity
Humidity stability over time ±1% ÷ ±3%
Dew point range for long-term tests +2 / +94 °C
Dew point range for short-term tests -20 / +2 °C
External dimensions (L x D x H) 1320 x 2235 x 2137 mm
Test space dimensions (L x D x H) 1000 x 1130 x 1020 mm
Test chamber volume: approx. 1152 liters
Max. load per grid: 50 kg
Maximum floor load of the test chamber: 100 kg
Refrigerants: R404A and R23
Power supply: 400V + 6%/-10% / 50Hz / 3P+N+PE
Rated power: 10.2 max. 17.5 kW
Rated current: 19.5 max. 32.0 A
Noise level: approx. 80 dB(A)
Weight: 1180 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
Hodpfx Aewfddwedrjnu
3. Leakage test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
您的广告已成功删除