Testo 480,湿度及风速测量仪Testo
480
Testo 480,湿度及风速测量仪
Testo
480
固定价格 不包含增值稅
€1,250
狀況
二手
位置
Tatabánya 

顯示圖片
显示地图
机器数据
价格和位置
固定价格 不包含增值稅
€1,250
- 位置:
- Vágóhid u. 2, 2800 Tatabánya, Magyarország

撥打
优惠详情
- 產品ID:
- A19612531
- 參考編號:
- 6687
- 最後更新:
- 於 21.07.2025
描述
Manufacturer: Testo
Model: 480
The Testo 480 features a built-in, high-precision differential pressure sensor, suitable for applications such as Pitot tube measurements, filter checks, and cleanroom monitoring. Its wide range of compatible probes allows measurement of the following parameters:
Air velocity and air volume (e.g., for fume hood testing)
Temperature
Relative humidity
Differential and absolute pressure
CO₂ concentration
Illuminance
PMV/PPD (comfort index)
Radiant heat
Turbulence intensity
WBGT index (heat stress)
The instrument can be customized with various optional probes and accessories (e.g., a wireless printer for on-site reporting).
Technical Specifications
Temperature Measurement
Pt100 Sensor
Measuring range: –100…+400 °C
Resolution: 0.01 °C
TC Type K (NiCr-Ni) Sensor
Measuring range: –200…+1370 °C
Accuracy: ±(0.3 °C + 0.1% of measured value)
Resolution: 0.1 °C
Relative Humidity (Capacitive Sensor)
Measuring range: 0…100 %RH
Resolution: 0.1 %RH
Air Velocity – Vane Anemometer
Ø 16 mm: 0.6…50 m/s | Resolution: 0.1 m/s
Ø 100 mm: 0.1…15 m/s | Resolution: 0.01 m/s
Air Velocity – Hot-wire Sensor
Measuring range: 0…20 m/s
Resolution: 0.01 m/s
CO₂ Concentration (Ambient Air)
Iedpfx Adow Au Nxsvea
Measuring range: 0…10,000 ppm
Resolution: 1 ppm
Comfort Level Measurement
Measuring range: 0…5 m/s
Resolution: 0.01 m/s
Differential Pressure – Built-in Piezoresistive Sensor
Measuring range: –100…+100 hPa
Accuracy:
0…25 hPa: ±(0.3 Pa + 1% of measured value)
25.001…100 hPa: ±(0.1 hPa + 1.5% of measured value)
Resolution: 0.001 hPa
Illuminance
Measuring range: 0…100,000 Lux
Resolution: 1 Lux
Absolute Pressure (Internal or External Probe)
Measuring range: 700…1100 hPa
Accuracy: ±3 hPa
Resolution: 0.1 hPa
General Technical Data
Weight: 435 g
Operating temperature: 0…+40 °C
Storage temperature: –20…+60 °C
Protection class: IP30
Connectable probes: 2 x TC Type K, 1 x differential pressure (internal), 3 x digital probes
Compliance: Directive 2004/108/EC
Battery life: approx. 17 hours (at 50% display brightness, without probes)
Display: Color graphic display
Power supply: Built-in rechargeable battery, mains charger for long-term measurements
Data transfer: USB cable or SD card
Memory capacity: 60,000,000 measured values
Model: 480
The Testo 480 features a built-in, high-precision differential pressure sensor, suitable for applications such as Pitot tube measurements, filter checks, and cleanroom monitoring. Its wide range of compatible probes allows measurement of the following parameters:
Air velocity and air volume (e.g., for fume hood testing)
Temperature
Relative humidity
Differential and absolute pressure
CO₂ concentration
Illuminance
PMV/PPD (comfort index)
Radiant heat
Turbulence intensity
WBGT index (heat stress)
The instrument can be customized with various optional probes and accessories (e.g., a wireless printer for on-site reporting).
Technical Specifications
Temperature Measurement
Pt100 Sensor
Measuring range: –100…+400 °C
Resolution: 0.01 °C
TC Type K (NiCr-Ni) Sensor
Measuring range: –200…+1370 °C
Accuracy: ±(0.3 °C + 0.1% of measured value)
Resolution: 0.1 °C
Relative Humidity (Capacitive Sensor)
Measuring range: 0…100 %RH
Resolution: 0.1 %RH
Air Velocity – Vane Anemometer
Ø 16 mm: 0.6…50 m/s | Resolution: 0.1 m/s
Ø 100 mm: 0.1…15 m/s | Resolution: 0.01 m/s
Air Velocity – Hot-wire Sensor
Measuring range: 0…20 m/s
Resolution: 0.01 m/s
CO₂ Concentration (Ambient Air)
Iedpfx Adow Au Nxsvea
Measuring range: 0…10,000 ppm
Resolution: 1 ppm
Comfort Level Measurement
Measuring range: 0…5 m/s
Resolution: 0.01 m/s
Differential Pressure – Built-in Piezoresistive Sensor
Measuring range: –100…+100 hPa
Accuracy:
0…25 hPa: ±(0.3 Pa + 1% of measured value)
25.001…100 hPa: ±(0.1 hPa + 1.5% of measured value)
Resolution: 0.001 hPa
Illuminance
Measuring range: 0…100,000 Lux
Resolution: 1 Lux
Absolute Pressure (Internal or External Probe)
Measuring range: 700…1100 hPa
Accuracy: ±3 hPa
Resolution: 0.1 hPa
General Technical Data
Weight: 435 g
Operating temperature: 0…+40 °C
Storage temperature: –20…+60 °C
Protection class: IP30
Connectable probes: 2 x TC Type K, 1 x differential pressure (internal), 3 x digital probes
Compliance: Directive 2004/108/EC
Battery life: approx. 17 hours (at 50% display brightness, without probes)
Display: Color graphic display
Power supply: Built-in rechargeable battery, mains charger for long-term measurements
Data transfer: USB cable or SD card
Memory capacity: 60,000,000 measured values