碳硫分析Leco
C 230 Anorganische Elementaranalytik
碳硫分析
Leco
C 230 Anorganische Elementaranalytik
固定价格 不包含增值稅
€5,700
狀況
二手
位置
Borken 

顯示圖片
显示地图
机器数据
价格和位置
固定价格 不包含增值稅
€5,700
- 位置:
- Einsteinstraße 8a, 46325 Borken, Deutschland

撥打
优惠详情
- 產品ID:
- A20546160
- 參考編號:
- 24420
- 最後更新:
- 於 17.11.2025
描述
Leco
LECO C230 CARBON ANALYZER
Carbon Determination C230
The LECO C230 Carbon Determiner is a microprocessor-based, software-controlled instrument for measuring the carbon and sulfur content in metals, ores, ceramics, and other inorganic materials. The C230 uses an induction furnace and measures carbon via infrared absorption.
Knodpfx Agoxxaxuofsd
The infrared (IR) source consists of a nichrome wire heated by resistance up to 8,500 °C. The IR source emits visible energy as well as all wavelengths of the infrared spectrum. For description purposes, carbon dioxide can be used; the same principle applies for sulfur detection. Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum. Energy from the IR source is absorbed as the gas passes through the cell, thereby preventing it from reaching the IR detector.
One IR cell is used both as a reference and for measurement. The total carbon content in the form of carbon dioxide is captured continuously and simultaneously. The initial reference level or baseline for the detector is set by passing oxygen through the cell to remove any remaining atmospheric gases.
Technical Data:
Required Gases:
Carrier gas: Oxygen, 99.5% pure, 40 psi
Pneumatic gas: Compressed air, nitrogen, or argon, 40 psi (2.76 bar), source must be oil- and water-free
Gas flow (based on nominal analysis time):
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Regulators:
Oxygen: 501-291 O₂ pressure regulator
Compressed air: 766-036 air pressure regulator
Inert gas: 764-216 inert gas regulator
Furnace: Induction, 18 MHz, 2.2 kW
Data Transfer: Included
Data Storage:
Without PC: 10 sample weights, 50 results, 5 methods
Without PC: Internal memory / Optional external display
Without PC: LCD display (16 x 26 characters)
Power Requirements:
Determinator: 230 V~, ± 10%, 50/60 Hz, single phase, 15 amp max
Operating current: 12 A
Standby current: 4 A
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in technical data; specifications subject to confirmation!)
For further questions, please feel free to contact us by phone.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
LECO C230 CARBON ANALYZER
Carbon Determination C230
The LECO C230 Carbon Determiner is a microprocessor-based, software-controlled instrument for measuring the carbon and sulfur content in metals, ores, ceramics, and other inorganic materials. The C230 uses an induction furnace and measures carbon via infrared absorption.
Knodpfx Agoxxaxuofsd
The infrared (IR) source consists of a nichrome wire heated by resistance up to 8,500 °C. The IR source emits visible energy as well as all wavelengths of the infrared spectrum. For description purposes, carbon dioxide can be used; the same principle applies for sulfur detection. Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum. Energy from the IR source is absorbed as the gas passes through the cell, thereby preventing it from reaching the IR detector.
One IR cell is used both as a reference and for measurement. The total carbon content in the form of carbon dioxide is captured continuously and simultaneously. The initial reference level or baseline for the detector is set by passing oxygen through the cell to remove any remaining atmospheric gases.
Technical Data:
Required Gases:
Carrier gas: Oxygen, 99.5% pure, 40 psi
Pneumatic gas: Compressed air, nitrogen, or argon, 40 psi (2.76 bar), source must be oil- and water-free
Gas flow (based on nominal analysis time):
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Regulators:
Oxygen: 501-291 O₂ pressure regulator
Compressed air: 766-036 air pressure regulator
Inert gas: 764-216 inert gas regulator
Furnace: Induction, 18 MHz, 2.2 kW
Data Transfer: Included
Data Storage:
Without PC: 10 sample weights, 50 results, 5 methods
Without PC: Internal memory / Optional external display
Without PC: LCD display (16 x 26 characters)
Power Requirements:
Determinator: 230 V~, ± 10%, 50/60 Hz, single phase, 15 amp max
Operating current: 12 A
Standby current: 4 A
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in technical data; specifications subject to confirmation!)
For further questions, please feel free to contact us by phone.
廣告是自動翻譯的,翻譯中可能會出現一些錯誤。
这些广告您可能也感兴趣。
小广告
Borken
7,415 km
扫描电子显微镜
ZeissEVO 50 inkl. EDS Ultim Max 100
ZeissEVO 50 inkl. EDS Ultim Max 100
小广告
Mainz
7,433 km
扫描电子显微镜 (SEM)
ZeissXB 350
ZeissXB 350
小广告
Köln
7,459 km
洁净空气工作台面
HeraguardHPH 15
HeraguardHPH 15
小广告
德国
11,295 km
过滤系统 - 渗透系统
Thermo Fisher ScientificECO 300
Thermo Fisher ScientificECO 300
小广告
Borken
7,415 km
高端元素分析仪
BrukerS8 TIGER WDXRF Spektrometer
BrukerS8 TIGER WDXRF Spektrometer
小广告
Borken
7,415 km
带湿度控制的气候试验箱,34升
WeissWKL 34/40 -40...+150°C
WeissWKL 34/40 -40...+150°C
小广告
Töltéstava
6,923 km
带自动进样器、FID、PC和软件的气相色谱仪
Agilent6890N
Agilent6890N
小广告
Freising
7,288 km
截面抛光机
JEOLIB-19530CP
JEOLIB-19530CP
小广告
Borken
7,415 km
盐雾腐蚀测试箱
VLMSAL 1000-FL PLC / V.715.362.520
VLMSAL 1000-FL PLC / V.715.362.520
小广告
Borken
7,415 km
System Trace 质谱仪
Thermo FinniganMS 2160 mit Finnigan DSQ II
Thermo FinniganMS 2160 mit Finnigan DSQ II
您的广告已成功删除
发生错误