安捷伦 Cary Eclipse 荧光分光光度计Agilent
Eclipse
安捷伦 Cary Eclipse 荧光分光光度计
Agilent
Eclipse
固定价格 不包含增值稅
€10,774
製造年份
2017
狀況
二手
位置
Duxford 

顯示圖片
显示地图
机器数据
价格和位置
固定价格 不包含增值稅
€10,774
- 位置:
- Duxford, UK

撥打
优惠详情
- 產品ID:
- A20568700
- 參考編號:
- 412977
- 最後更新:
- 於 19.11.2025
描述
This listing is for a Agilent Eclipse Fluorescence Spectrometer.
The unit is in full working condition and is ready for immediate release.
Supplied with cables, software disk, License key,spare diffuser and Neutral density attenuator.
Bsdpexx Ax Refx Afpsdk
The Agilent Cary Eclipse fluorescence spectrometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be achieved through various accessories, including temperature control and solid sample handling, automatic polarizers, and a microplate reader for high sample throughput.
Type:Benchtop fluorescence spectrometer
Control Software :Cary WinFLR
Light Source:Xenon flash lamp (80 Hz) with 10-year warranty on new instruments
Maximum Scanning Speed :24,000 nm/min
Modes of Operation:Fluorescence,Phosphorescence,Chemiluminescence,Biolumi nescence,Time resolved phosphorescence.
Power Requirements:100-240 VAC, 50/60 Hz
Spectral Bandwidth Emission: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm & 10 nm round nm
Excitation: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm & 10 nm round nm
Wavelength Accuracy:± 1.5 nm
Wavelength Range:Operational emission: 200 - 900 nm
Operational excitation: 200 - 900 nm
Depth:644 mm
Height:271 mm
Weight:30 kg
Width:608 mm
The unit is in full working condition and is ready for immediate release.
Supplied with cables, software disk, License key,spare diffuser and Neutral density attenuator.
Bsdpexx Ax Refx Afpsdk
The Agilent Cary Eclipse fluorescence spectrometer is sensitive, accurate, and flexible. Ideal for use as a routine fluorometer, the Cary Eclipse can easily be switched between fluorescence, phosphorescence, chemiluminescence, and bioluminescence measurements. Additional flexibility can be achieved through various accessories, including temperature control and solid sample handling, automatic polarizers, and a microplate reader for high sample throughput.
Type:Benchtop fluorescence spectrometer
Control Software :Cary WinFLR
Light Source:Xenon flash lamp (80 Hz) with 10-year warranty on new instruments
Maximum Scanning Speed :24,000 nm/min
Modes of Operation:Fluorescence,Phosphorescence,Chemiluminescence,Biolumi nescence,Time resolved phosphorescence.
Power Requirements:100-240 VAC, 50/60 Hz
Spectral Bandwidth Emission: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm & 10 nm round nm
Excitation: 1.5 nm, 2.5 nm, 5 nm, 10 nm, 20 nm & 10 nm round nm
Wavelength Accuracy:± 1.5 nm
Wavelength Range:Operational emission: 200 - 900 nm
Operational excitation: 200 - 900 nm
Depth:644 mm
Height:271 mm
Weight:30 kg
Width:608 mm