描述
We offer the following for sale here:
Item number: 12878
Prince Technologies PrinCe 560 Capillary Zone Electrophoresis System
Connections:
Mains, HV control, parallel port A, parallel port B,
Psxh8M
Series port A (RS232), Series port B (RS232).
Technical data:
Injection method: up to 650 min, in 0.01 min steps; Hydrodynamics: 180 - 250 m bar,
in 1 mbar steps, electrokinetics; -30 to + 30 kV, current and/or voltage
Flow/pressure range: 0 to +3000 mbar from DCI device.
Volt range: 30 kV to +30 kV
Current range: -200uA to +200uA
Rise: Programmable volt or amp rise
Polarity reversal: Programmable before and during the sample run.
Autosampler: Position carousel for 30/48 sample and buffer vials. Variable vial size, including Eppendorf micro centrifuge tubes.
Buffer volume: Max. 4 ml
Sample volume: Min 10ul, max 4 ml.
Temperature control: sample and buffer 4 C to 40 C.
Lapillary output: 5 C to below 60 C
Detector: Allows the use of: UV/Vis, fluorescence, diode array, LIF, conductivity, electrochemical and MS.
Year 2004
Hfsdpfx Aju Eb D Hjdrjn
Model PrinCe 560 0500.022/CR
S/N: 50-14-05-3-23
Dimensions:50x50x54 cm
Weight: 35 kg
without function test
Item number: 12878
Prince Technologies PrinCe 560 Capillary Zone Electrophoresis System
Connections:
Mains, HV control, parallel port A, parallel port B,
Psxh8M
Series port A (RS232), Series port B (RS232).
Technical data:
Injection method: up to 650 min, in 0.01 min steps; Hydrodynamics: 180 - 250 m bar,
in 1 mbar steps, electrokinetics; -30 to + 30 kV, current and/or voltage
Flow/pressure range: 0 to +3000 mbar from DCI device.
Volt range: 30 kV to +30 kV
Current range: -200uA to +200uA
Rise: Programmable volt or amp rise
Polarity reversal: Programmable before and during the sample run.
Autosampler: Position carousel for 30/48 sample and buffer vials. Variable vial size, including Eppendorf micro centrifuge tubes.
Buffer volume: Max. 4 ml
Sample volume: Min 10ul, max 4 ml.
Temperature control: sample and buffer 4 C to 40 C.
Lapillary output: 5 C to below 60 C
Detector: Allows the use of: UV/Vis, fluorescence, diode array, LIF, conductivity, electrochemical and MS.
Year 2004
Hfsdpfx Aju Eb D Hjdrjn
Model PrinCe 560 0500.022/CR
S/N: 50-14-05-3-23
Dimensions:50x50x54 cm
Weight: 35 kg
without function test