Fresenius Vial Pilot A2 医用输液注射泵(注射泵)Fresenius
Pilot A2
Fresenius Vial Pilot A2 医用输液注射泵(注射泵)
Fresenius
Pilot A2
VB 不含增值税
€235
状况
二手
位置
Borken 

基本数据
价格和位置
VB 不含增值税
€235
- 位置:
- Borken, 德国

拨打
优惠详情
- 广告编号:
- A23232100
- 参考编号:
- 74856
- 更新:
- 最近更新时间为 28.10.2026
描述
Fresenius Pilot A2 Syringe Pump
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
The device is used in everyday medical practice for the continuous, precisely controlled administration of highly potent medications, anesthetics, or infusion solutions via standard syringes.
The device features a clear control panel, a digital display for flow rate indication, as well as automatic safety and alarm functions.
Thanks to the already mounted, robust original bracket on the back, the pump can be quickly and securely attached to infusion stands, intensive care beds, or standardized medical rails.
Features:
- High flexibility: Automatic recognition and compatibility with common 20 ml and 50 ml Luer-Lock syringes (presets for, among others, BD Plastipak, Braun Perfusor, and Monoject can be read directly on the housing).
- Clear control panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for precise flow rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery level.
- Mobility: Integrated battery for bridging during patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Flow rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1% (drive mechanism), ± 2% (syringe)
Voltage supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety functions: Acoustic and visual alarm systems (e.g., in case of occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2013
"Everything from one source: We would be happy to offer you suitable bank financing for your project."
You can find more items - new and used - in our shop!
International shipping costs on request!
Rcodpfo Af Uxfox Ai Rsh
该广告为自动翻译,可能存在翻译错误。
You are bidding on an original Fresenius Vial Pilot A2 syringe pump (often also referred to as a perfusor).
This is a proven, highly precise medical table and stand device for the continuous and precisely dosed administration of medications and infusion solutions.
The device is used in everyday medical practice for the continuous, precisely controlled administration of highly potent medications, anesthetics, or infusion solutions via standard syringes.
The device features a clear control panel, a digital display for flow rate indication, as well as automatic safety and alarm functions.
Thanks to the already mounted, robust original bracket on the back, the pump can be quickly and securely attached to infusion stands, intensive care beds, or standardized medical rails.
Features:
- High flexibility: Automatic recognition and compatibility with common 20 ml and 50 ml Luer-Lock syringes (presets for, among others, BD Plastipak, Braun Perfusor, and Monoject can be read directly on the housing).
- Clear control panel: Wipe-resistant, hygienic foil keyboard with a clear digital LED display for precise flow rate indication.
- Comprehensive safety system: Visual and audible pre-alarms and main alarms in case of occlusion, incorrect syringe positioning, power failure, or low battery level.
- Mobility: Integrated battery for bridging during patient transport or sudden power failure.
Technical data:
Manufacturer: Fresenius Vial SA (Vial Medical)
Model: Pilot A2
Device type: Infusion syringe pump (perfusor)
Syringe compatibility: Suitable for standardized 20 ml and 50 ml Luer-Lock syringes
Flow rate adjustable: from 0.1 to 400 ml/h
Accuracy: ± 1% (drive mechanism), ± 2% (syringe)
Voltage supply: Mains operation: 230 V ~ 50/60 Hz
Battery operation: Integrated battery (for power failure/transport)
Power consumption: Max. 23 VA
Dimensions (H x W x D): Approx. 120 x 330 x 155 mm
Weight: Approx. 2.2 kg
Housing material: Robust, impact-resistant polycarbonate
Safety functions: Acoustic and visual alarm systems (e.g., in case of occlusion/pressure, syringe positioning, power failure, or low battery)
Year of manufacture: 2013
"Everything from one source: We would be happy to offer you suitable bank financing for your project."
You can find more items - new and used - in our shop!
International shipping costs on request!
Rcodpfo Af Uxfox Ai Rsh
该广告为自动翻译,可能存在翻译错误。
供應商
注意: 免费注册或登录,以获取所有信息。
注册于: 2008
535 在线广告
发送询价
电话 & 传真
+49 2862 ... 广告
这些广告您可能也感兴趣。
成功
您的消息已发送。
小广告
Borken
7,417 km
Fresenius Vial Pilot A2 医用输液注射泵(Perfusor)
FreseniusPilot A2
FreseniusPilot A2
成功
您的消息已发送。
小广告
Borken
7,417 km
Fresenius Vial Pilot A2 医用输液注射泵(Perfusor)
FreseniusPilot A2
FreseniusPilot A2
成功
您的消息已发送。
小广告
Borken
7,417 km
Fresenius Vial Pilot A2 医用输液注射泵(注射泵)
FreseniusPilot A2
FreseniusPilot A2
您的广告已成功删除
发生错误