Bruker Maldi-Tof Microflex 质谱仪
Bruker Microflex

狀況
二手
位置
Duxford 英国
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
Bruker Maldi-Tof Microflex 质谱仪 Bruker Microflex
more Images
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
Bruker Microflex
顯示圖片
显示地图

机器数据

機器描述:
Bruker Maldi-Tof Microflex 质谱仪
製造商:
Bruker
模型:
Microflex
狀況:
二手

价格和位置

位置:
Duxford, UK 英国
撥打

优惠详情

產品ID:
A20123245
參考編號:
43080.2B
最後更新:
於 02.10.2025

描述

This listing is for the This listing is for the Bruker microflex spectrometer mass

The unit is in full working condition and is ready for immediate use

The Bruker Microflex is a Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometer (MALDI-TOF MS), primarily used for rapid identification of microorganisms, biomolecules (like proteins and peptides), and polymers. It is part of Bruker’s MALDI Biotyper series

Key Components:

Laser Source: Nitrogen or solid-state laser (commonly 337 nm UV)

Hfedpfx Adexhdxqeren
Ion Source: Vacuum chamber with MALDI target plate

Flight Tube: Measures time-of-flight of ions

Detector: Converts ion arrival times into a mass spectrum

MALDI Target Plate: Metal plate for spotting samples mixed with matrix

How It Works (Simplified):

Sample Prep: Mix analyte with a MALDI matrix (e.g., α-cyano-4-hydroxycinnamic acid).

Laser Ionization: Laser hits the matrix, causing it to ionize the sample.

Ion Acceleration: Ions accelerated into TOF analyzer.

Detection: Time-of-flight is measured; smaller ions reach the detector faster.

Spectrum: Mass/charge ratio (m/z) plotted vs intensity.

Physical Specs (Approximate):

Footprint: Desktop size (about 80 cm width)

Weight: ~100–120 kg (varies by model/version)

Power: Standard lab electrical supply

Environment: Requires clean, stable temp/humidity condition

供應商

註冊時間: 2019

524 在线广告

撥打

提交申請

土地us 
德国
奥地利
瑞士
美国
英国
法国
比利时
西班牙
墨西哥
意大利
荷兰
波兰
俄罗斯联邦
白俄罗斯(白俄罗斯共和国)
乌克兰
爱沙尼亚
土耳其
新西兰
爱尔兰
捷克共和国
丹麦
芬兰
瑞典
挪威
卢森堡
希腊
立陶宛
拉脱维亚
冰岛
葡萄牙
巴西
委内瑞拉
阿根廷
匈牙利
斯洛伐克
罗马尼亚
摩尔多瓦
斯洛文尼亚
塞尔维亚
黑山
阿尔巴尼亚
克罗地亚
保加利亚
北马其顿
波斯尼亚和黑塞哥维那
以色列
埃及
摩洛哥
印度
印度尼西亚
韩国
日本
泰国
马来西亚
越南
China
中国台湾
伊朗
孟加拉国
阿富汗
提示: 您的请求将被转发给该机械类别的所有卖家。 这样您可以收到大量的报价。
无法发送请求。请稍后再试。

電話 & 傳真