BAC S15E 1018-10 LE 开放式蒸发式冷却塔 冷却塔 间接冷却器 制冷系统BAC
S15E 1018-10 LE
BAC S15E 1018-10 LE 开放式蒸发式冷却塔 冷却塔 间接冷却器 制冷系统
BAC
S15E 1018-10 LE
VB 不含增值税
€26,800
状况
二手
位置
Borken 

基本数据
价格和位置
VB 不含增值税
€26,800
- 位置:
- 46325 Borken, Deutschland

拨打
优惠详情
- 广告编号:
- A21340202
- 参考编号:
- 60821
- 更新:
- 最近更新时间为 13.11.2026
描述
BAC S1500E Cooling Tower
The BAC S15E 1018-10-LE is a high-performance, open-circuit cooling tower from the S1500E series manufactured by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are priorities.
Technology
Patented BACross III fill media system, which allows for easy inspection of the fill to prevent biological growth (e.g., Legionella).
Key Features of the S1500E Series
Maintenance access: A large, inward-swinging access door and internal maintenance platforms allow technicians to conveniently perform inspections while standing inside the unit.
Hygiene control: The design minimizes standing water and protects against sunlight through special air inlet elements, reducing algae growth.
Flexibility: The single-sided air intake allows the cooling tower to be installed even in confined spaces or directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial cooling: Used in factories for process cooling.
HVAC: Used in large building complexes as part of a central chiller system.
Refrigeration: Used as a condenser in commercial refrigeration systems.
Cooling Capacity
An open evaporative cooling tower does not have a fixed, single kW cooling capacity, as the actual performance depends entirely on the thermodynamic ambient conditions and system temperatures.
The model is designed for maximum flow rates of up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity of this model is in the range of approximately 1,200 kW to 2,100 kW.
Why does the cooling capacity vary?
Wet-bulb temperature (outside air): The cooler and drier the ambient air, the more water can evaporate, and the higher the cooling capacity.
Water temperatures: The performance changes significantly depending on the warm water inlet temperature (e.g., 35 °C) and the cold water outlet temperature (e.g., 29 °C).
Air volume flow: According to BAC's technical data, the S15E 1018-10 LE model actively moves 60.0 m³/s of air through three installed 11.0 kW fan motors.
If this air volume is reduced by a frequency inverter (e.g., during night operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This is the most important thermodynamic limit. It describes the difference between the desired cold water temperature and the physically determined wet-bulb temperature. The closer the cold water is cooled to the wet-bulb temperature (smaller approach), the less kW of power the tower can provide.
Technical Data:
Fan and Air Data
- Air volume flow: 60.0 m³/s (generated in suction operation)
- Fan motors: 3x 11.0 kW (axial fans)
- Technology: Integrated belt drive
- Water flow: 198 l/s
Hydraulic Connections
Ledpeynkbmjfx Appeai
- Water inlet: 1x DN 250 (nominal size ND 250 mm)
- Water outlet: 1x DN 300 (nominal size ND 300 mm)
- Make-up water connection: 1x DN 40 (ND 40 mm)
- Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Dimensions and Weights
- Operating weight: 11,446 kg (including water fill up to overflow)
- Shipping weight: 5,350 kg (empty weight)
- Heaviest single part: 3,114 kg (for installation)
该广告为自动翻译,可能存在翻译错误。
The BAC S15E 1018-10-LE is a high-performance, open-circuit cooling tower from the S1500E series manufactured by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large HVAC systems where high efficiency and ease of maintenance are priorities.
Technology
Patented BACross III fill media system, which allows for easy inspection of the fill to prevent biological growth (e.g., Legionella).
Key Features of the S1500E Series
Maintenance access: A large, inward-swinging access door and internal maintenance platforms allow technicians to conveniently perform inspections while standing inside the unit.
Hygiene control: The design minimizes standing water and protects against sunlight through special air inlet elements, reducing algae growth.
Flexibility: The single-sided air intake allows the cooling tower to be installed even in confined spaces or directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial cooling: Used in factories for process cooling.
HVAC: Used in large building complexes as part of a central chiller system.
Refrigeration: Used as a condenser in commercial refrigeration systems.
Cooling Capacity
An open evaporative cooling tower does not have a fixed, single kW cooling capacity, as the actual performance depends entirely on the thermodynamic ambient conditions and system temperatures.
The model is designed for maximum flow rates of up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity of this model is in the range of approximately 1,200 kW to 2,100 kW.
Why does the cooling capacity vary?
Wet-bulb temperature (outside air): The cooler and drier the ambient air, the more water can evaporate, and the higher the cooling capacity.
Water temperatures: The performance changes significantly depending on the warm water inlet temperature (e.g., 35 °C) and the cold water outlet temperature (e.g., 29 °C).
Air volume flow: According to BAC's technical data, the S15E 1018-10 LE model actively moves 60.0 m³/s of air through three installed 11.0 kW fan motors.
If this air volume is reduced by a frequency inverter (e.g., during night operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This is the most important thermodynamic limit. It describes the difference between the desired cold water temperature and the physically determined wet-bulb temperature. The closer the cold water is cooled to the wet-bulb temperature (smaller approach), the less kW of power the tower can provide.
Technical Data:
Fan and Air Data
- Air volume flow: 60.0 m³/s (generated in suction operation)
- Fan motors: 3x 11.0 kW (axial fans)
- Technology: Integrated belt drive
- Water flow: 198 l/s
Hydraulic Connections
Ledpeynkbmjfx Appeai
- Water inlet: 1x DN 250 (nominal size ND 250 mm)
- Water outlet: 1x DN 300 (nominal size ND 300 mm)
- Make-up water connection: 1x DN 40 (ND 40 mm)
- Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Dimensions and Weights
- Operating weight: 11,446 kg (including water fill up to overflow)
- Shipping weight: 5,350 kg (empty weight)
- Heaviest single part: 3,114 kg (for installation)
该广告为自动翻译,可能存在翻译错误。
供應商
注意: 免费注册或登录,以获取所有信息。
注册于: 2008
532 在线广告
发送询价
电话 & 传真
+49 2862 ... 广告
这些广告您可能也感兴趣。
成功
您的消息已发送。
小广告
Dinkelscherben
7,368 km
输送带上升输送带输送系统
die magnetprofis2021100803
die magnetprofis2021100803
成功
您的消息已发送。
小广告
Hillegom
7,529 km
冷却机
YorkYLCS1110HA 50Y A
YorkYLCS1110HA 50Y A
成功
您的消息已发送。
小广告
罗马尼亚
7,492 km
Engel DUO 3550/400 pico
EngelDUO 3550/400 pico
EngelDUO 3550/400 pico
成功
您的消息已发送。
小广告
Hillegom
7,529 km
干式冷却器
CaberoGCHSD089MB/X7S-40 Y V
CaberoGCHSD089MB/X7S-40 Y V
成功
您的消息已发送。
小广告
Niedźwiedź
6,680 km
制冷压缩机
DWM CopelandD6DH3-3500-AWM/D
DWM CopelandD6DH3-3500-AWM/D
成功
您的消息已发送。
小广告
Niedźwiedź
6,680 km
80-120立方米冷冻库完整设备套装
RivacoldZF24KVE-TWD
RivacoldZF24KVE-TWD
成功
您的消息已发送。
小广告
Wrocław
6,824 km
注塑机
EngelDUO 5160/700
EngelDUO 5160/700
成功
您的消息已发送。
小广告
德国
7,232 km
冷却塔
Karlsruhe (Gohl-KTK)K 18-28-3
Karlsruhe (Gohl-KTK)K 18-28-3
成功
您的消息已发送。
小广告
Niedźwiedź
6,680 km
冷凝器
GüntnerGVH 090.2A/2x5-N(D)
GüntnerGVH 090.2A/2x5-N(D)
成功
您的消息已发送。
小广告
Hillegom
7,529 km
冷却塔
EvapcoATW 36-4M
EvapcoATW 36-4M
您的广告已成功删除
发生错误