BAC S1500E Cooling Tower
The BAC S15E 1018-10-LE is a high-performance, open cooling tower from the S1500E series manufactured by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large air conditioning (HVAC) systems where high efficiency and ease of maintenance are paramount.
Technology
Patented BACross III fill system, which allows for easy inspection of the fins to prevent biological growth (e.g., Legionella).
Main Features of the S1500E Series
Maintenance Access: A large, inward-swinging access door, as well as internal maintenance platforms, allow technicians to conveniently perform inspections while standing inside the unit.
Hygiene Control: The design minimizes standing water and protects against sunlight through special air inlet elements, which reduces algae growth.
Flexibility: Thanks to the single-sided air inlet, the cooling tower can also be installed in confined spaces or directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial Cooling: Used in factories for process cooling.
Air Conditioning (HVAC): Used in large building complexes as part of a central chilled water system.
Refrigeration: Used as a condenser in commercial refrigeration systems.
Cooling Capacity
An open evaporative cooling tower does not have a fixed, single kW cooling capacity because the actual performance depends entirely on the prevailing thermodynamic ambient conditions and the system temperatures.
This model is designed for maximum flow rates of up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity of this model is in the range of approximately 1,200 kW to 2,100 kW.
Why does the cooling capacity vary?
Wet-bulb temperature (outside air): The cooler and drier the ambient air, the more water can evaporate, and the higher the cooling capacity.
Water temperatures: The performance changes significantly depending on the inlet warm water temperature (e.g., 35 °C) and the outlet cold water temperature (e.g., 29 °C).
Air volume flow: According to the technical data from BAC, the S15E 1018-10 LE model actively moves 60.0 m³/s of air through three 11.0 kW fan motors.
If this air volume is reduced by a frequency converter (e.g., during nighttime operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This is the most important thermodynamic limit. It describes the difference between the desired cold water temperature and the physically determined wet-bulb temperature. The closer the cold water is cooled to the wet-bulb temperature (smaller approach), the less kW of cooling capacity the tower produces.
Technical Data:
Fan & Air Data
Air volume flow: 60.0 m³/s (generated in draw-through operation)
Fan motors: 3x 11.0 kW (axial fans)
Technology: Integrated belt drive
Water flow: 198 l/s
Hydraulic Connections
Water inlet (fluid inlet): 1x DN 250 (nominal size ND 250 mm)
Water outlet (fluid outlet): 1x DN 300 (nominal size ND 300 mm)
Make-up water connection: 1x DN 40 (ND 40 mm)
Overflow / drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Dimensions & Weights
Operating weight: 11,446 kg (including water filling up to the overflow)
Shipping weight: 5,350 kg (empty weight)
Dcedpfx Aoynkbmsntsn
Heaviest single part: 3,
该广告为自动翻译,可能存在翻译错误。
The BAC S15E 1018-10-LE is a high-performance, open cooling tower from the S1500E series manufactured by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large air conditioning (HVAC) systems where high efficiency and ease of maintenance are paramount.
Technology
Patented BACross III fill system, which allows for easy inspection of the fins to prevent biological growth (e.g., Legionella).
Main Features of the S1500E Series
Maintenance Access: A large, inward-swinging access door, as well as internal maintenance platforms, allow technicians to conveniently perform inspections while standing inside the unit.
Hygiene Control: The design minimizes standing water and protects against sunlight through special air inlet elements, which reduces algae growth.
Flexibility: Thanks to the single-sided air inlet, the cooling tower can also be installed in confined spaces or directly against walls.
Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
Industrial Cooling: Used in factories for process cooling.
Air Conditioning (HVAC): Used in large building complexes as part of a central chilled water system.
Refrigeration: Used as a condenser in commercial refrigeration systems.
Cooling Capacity
An open evaporative cooling tower does not have a fixed, single kW cooling capacity because the actual performance depends entirely on the prevailing thermodynamic ambient conditions and the system temperatures.
This model is designed for maximum flow rates of up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity of this model is in the range of approximately 1,200 kW to 2,100 kW.
Why does the cooling capacity vary?
Wet-bulb temperature (outside air): The cooler and drier the ambient air, the more water can evaporate, and the higher the cooling capacity.
Water temperatures: The performance changes significantly depending on the inlet warm water temperature (e.g., 35 °C) and the outlet cold water temperature (e.g., 29 °C).
Air volume flow: According to the technical data from BAC, the S15E 1018-10 LE model actively moves 60.0 m³/s of air through three 11.0 kW fan motors.
If this air volume is reduced by a frequency converter (e.g., during nighttime operation or in winter), the cooling capacity decreases in a controlled manner.
Approach: This is the most important thermodynamic limit. It describes the difference between the desired cold water temperature and the physically determined wet-bulb temperature. The closer the cold water is cooled to the wet-bulb temperature (smaller approach), the less kW of cooling capacity the tower produces.
Technical Data:
Fan & Air Data
Air volume flow: 60.0 m³/s (generated in draw-through operation)
Fan motors: 3x 11.0 kW (axial fans)
Technology: Integrated belt drive
Water flow: 198 l/s
Hydraulic Connections
Water inlet (fluid inlet): 1x DN 250 (nominal size ND 250 mm)
Water outlet (fluid outlet): 1x DN 300 (nominal size ND 300 mm)
Make-up water connection: 1x DN 40 (ND 40 mm)
Overflow / drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Dimensions & Weights
Operating weight: 11,446 kg (including water filling up to the overflow)
Shipping weight: 5,350 kg (empty weight)
Dcedpfx Aoynkbmsntsn
Heaviest single part: 3,
该广告为自动翻译,可能存在翻译错误。
供應商
注意: 免费注册或登录,以获取所有信息。
上次在线:上周
注册于: 2008
541 在线广告
发送询价
电话 & 传真
+49 2862 ... 广告
这些广告您可能也感兴趣。
成功
您的消息已发送。
小广告
Dinkelscherben
7,368 km
输送带上升输送带输送系统
die magnetprofis2021100803
die magnetprofis2021100803
成功
您的消息已发送。
小广告
Łęczna
6,430 km
冷水机/热泵
New Chiller / Heat pumpBlue Box 16/18 kW | With warranty
New Chiller / Heat pumpBlue Box 16/18 kW | With warranty
成功
您的消息已发送。
小广告
Niedźwiedź
6,680 km
冷气机
GüntnerS-GGN 066C/27
GüntnerS-GGN 066C/27
成功
您的消息已发送。
小广告
Remseck am Neckar
7,426 km
比泽尔工业制冷复叠系统
Bitzer Verbundanlage6J-22.2Y-40P/ 4H-15.2Y-40P
Bitzer Verbundanlage6J-22.2Y-40P/ 4H-15.2Y-40P
成功
您的消息已发送。
小广告
德国
7,232 km
冷却塔
EvapcoAT-17-4J9
EvapcoAT-17-4J9
成功
您的消息已发送。
小广告
Hillegom
7,529 km
冷却机
YorkYLCS1110HA 50Y A
YorkYLCS1110HA 50Y A
成功
您的消息已发送。
小广告
Niedźwiedź
6,680 km
制冷压缩机
DWM CopelandD6DH3-3500-AWM/D
DWM CopelandD6DH3-3500-AWM/D
成功
您的消息已发送。
小广告
罗马尼亚
7,492 km
Engel DUO 3550/400 pico
EngelDUO 3550/400 pico
EngelDUO 3550/400 pico
成功
您的消息已发送。
小广告
Niedźwiedź
6,680 km
冷凝器
GüntnerGVH 090.2A/2x5-N(D)
GüntnerGVH 090.2A/2x5-N(D)
成功
您的消息已发送。
小广告
Hillegom
7,529 km
干式冷却器
CaberoGCHSD089MB/X7S-40 Y V
CaberoGCHSD089MB/X7S-40 Y V
您的广告已成功删除
发生错误